Automated Tools for Contour Review in Radiotherapy
Barbara Marquez, BA (Advisor: Laurence Court, PhD)
Peer review of organ-at-risk and target volume delineation is essential for patient safety and optimization of treatment outcomes. Peer review makes a substantial impact on patient outcomes, reporting notable rates of plan changes when reviewed and worse survival when patient cases are not reviewed. In around half of revised cases, target volume change is the required cause for modification (related to tumor control); in one in ten cases, it is normal tissue sparing (related to treatment toxicity). Accessibility to practicing routine peer review (especially of contours) is highly dependent on the presence of sub-specialized radiation oncology staff and their expensive time, making the workflow and qualitative decision-making inconsistent across clinical practices. In pursuing the automation of the contour review process, especially with the wide adoption of auto-contouring to clinical practice, we aim to mitigate time and specialty resource shortages to this critical clinical practice.
The purpose of this study was to develop automated tools that can accurately identify sub-optimal contours (inadequate target coverage, sub-optimal delineation of organs at risk to reduce toxicity), agnostic of their manual or automated generation. To accomplish this, we first examined the relationship between geometric and dosimetric agreement metrics amongst normal tissue auto-contours and clinical contours in discerning whether the current state of automated contour QA (which mainly relies on geometric comparisons) was appropriately defining contour errors and deploying effective metrics for error detection. We tested this relationship over a substantial dataset of head and neck patients. Using this knowledge, we further examined the necessity of incorporating dose-based comparisons into normal tissue contour QA to improve the detection of clinically significant errors. A two-contour QA system was developed, leveraging an independent auto-contouring system to cross-validate a primary auto-contouring system in its performance against clinical manual delineations. We employed a logistic regression model as a means by which geometric and dosimetric comparisons in a two-contour QA system can flag potential errors in a primary auto-contouring system compared to the clinical ground truth. Finally, we explored automated contour QA of target contours by employing statistical process control to explore an interpretable and scalable approach for continuous contour quality monitoring of internal target volumes in cervical cancer. Control charts were generated to establish data-driven control limits for geometric and dosimetric comparisons between auto- and clinical target contours, allowing for automated flagging of deviations from expected contouring norms. This dissertation advances automated contour QA by providing a framework for artificial intelligence-assisted contour verification that is interpretable, scalable, and clinically relevant. The tools developed in this work are expected to improve real-time contour QA through implementation to a web-based automated, expert peer review system, enabling clinics to practice contour peer review despite disparities in expertise and resources.
Advisory Committee:
- Laurence Court, PhD, Chair
- David Fuentes, PhD
- Anuja Jhingran, MD
- Christine Peterson, PhD
- Julliane Pollard-Larkin, PhD
- Surendra Prajapati, PhD
- Thomas Whitaker, PhD
Join via Zoom (Please contract Ms. Barbara Marquez for her Zoom meeting info.)
Automated Tools for Contour Review in Radiotherapy
Barbara Marquez, BA (Advisor: Laurence Court, PhD)
Peer review of organ-at-risk and target volume delineation is essential for patient safety and optimization of treatment outcomes. Peer review makes a substantial impact on patient outcomes, reporting notable rates of plan changes when reviewed and worse survival when patient cases are not reviewed. In around half of revised cases, target volume change is the required cause for modification (related to tumor control); in one in ten cases, it is normal tissue sparing (related to treatment toxicity). Accessibility to practicing routine peer review (especially of contours) is highly dependent on the presence of sub-specialized radiation oncology staff and their expensive time, making the workflow and qualitative decision-making inconsistent across clinical practices. In pursuing the automation of the contour review process, especially with the wide adoption of auto-contouring to clinical practice, we aim to mitigate time and specialty resource shortages to this critical clinical practice.
The purpose of this study was to develop automated tools that can accurately identify sub-optimal contours (inadequate target coverage, sub-optimal delineation of organs at risk to reduce toxicity), agnostic of their manual or automated generation. To accomplish this, we first examined the relationship between geometric and dosimetric agreement metrics amongst normal tissue auto-contours and clinical contours in discerning whether the current state of automated contour QA (which mainly relies on geometric comparisons) was appropriately defining contour errors and deploying effective metrics for error detection. We tested this relationship over a substantial dataset of head and neck patients. Using this knowledge, we further examined the necessity of incorporating dose-based comparisons into normal tissue contour QA to improve the detection of clinically significant errors. A two-contour QA system was developed, leveraging an independent auto-contouring system to cross-validate a primary auto-contouring system in its performance against clinical manual delineations. We employed a logistic regression model as a means by which geometric and dosimetric comparisons in a two-contour QA system can flag potential errors in a primary auto-contouring system compared to the clinical ground truth. Finally, we explored automated contour QA of target contours by employing statistical process control to explore an interpretable and scalable approach for continuous contour quality monitoring of internal target volumes in cervical cancer. Control charts were generated to establish data-driven control limits for geometric and dosimetric comparisons between auto- and clinical target contours, allowing for automated flagging of deviations from expected contouring norms. This dissertation advances automated contour QA by providing a framework for artificial intelligence-assisted contour verification that is interpretable, scalable, and clinically relevant. The tools developed in this work are expected to improve real-time contour QA through implementation to a web-based automated, expert peer review system, enabling clinics to practice contour peer review despite disparities in expertise and resources.
Advisory Committee:
- Laurence Court, PhD, Chair
- David Fuentes, PhD
- Anuja Jhingran, MD
- Christine Peterson, PhD
- Julliane Pollard-Larkin, PhD
- Surendra Prajapati, PhD
- Thomas Whitaker, PhD
Join via Zoom (Please contract Ms. Barbara Marquez for her Zoom meeting info.)
", "startDate":"2025-4-1", "endDate":"2025-4-1", "startTime":"11:00", "endTime":"12:00", "location":"UTHealth Houston, MD Anderson Cancer Center, AT&T Auditorium and via Zoom", "label":"Add to Calendar", "options":[ "Apple", "Google", "iCal", "Microsoft365", "MicrosoftTeams", "Yahoo" ], "timeZone":"America/Chicago", "trigger":"click", "inline":true, "listStyle":"modal", "iCalFileName":"Reminder-Event" }